APPENDIX
88
ee sustain loop end word (nsb)
ee sustain loop end word (msb)
00 loop type (forwards only)
f7 EOX
Sample period is fixed at (1/26.04)kHz = 9602 HEX in nanoseconds.
MMA Data Packet f0 system exclusive
7e
0c MIDI base channel (0 to 15)
02 MMA exclusive number
cc packet count (0 to 127)
120 data bytes
xx checksum (exclusive OR of above 124
bytes)
f7 EOX
The (120) data bytes represent (60) 12-bit linear SP 1200 data words:
byte 0: 0bbbbbbb bbbbbbb = 7 ms bits of data word 0
byte 1: 0aaaaa00 aaaaa = 5 ls bits of data word 0
byte 2: 0ddddddd ddddddd = 7 ms bits of data word 1
byte 3: 0ccccc00 ccccc = 5 ls bits of data word 1
——etc———
byte 119: 0yyyyy00 yyyyyyy = 5 ls bits of data word 59
The 12-bit data is in “complement offset binary” format: most negative value = 000 hex,
“zero” = 800 hex, most positive = fff hex