PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301 187Maintenance Procedures
Cleaning the Air Purge Filter
Cleaning the Air Purge Filter depends on the paper dust levels. If there is a high
level of dust, the filter should be checked and cleaned at least once a day. If there
are lesser amounts of paper dust, then the interval should be a minimum of every
other day.
If the Air Purge Filter requires frequent cleaning, you might consider relocation of
the blower to a cleaner environment. Failure to check and clean the filter will cause
premature failure of the purge blower motor and frame down time.
1. Turn off power to the purge blower using the switch on the blower.
2. Turn off the power at the power distribution center.
3. Remove the cylindrical fiber filter.
4. Blow compressed air into the inside of the filter to clean it.
If the metal screen filter is also dirty, clean it the same way.
5. Replace the filter. Restart the blower.
Note: Keep the Scanning Platform well sealed and the doors fully closed
at all times, except during maintenance. Positive air flow is required
for reliable operation.